How to prime a deep well water pump is often a straightforward process that can restore water service quickly when a jet pump loses prime. Here’s the quick answer:

Quick Steps to Prime a Deep Well Pump:

  1. Turn off the power at the circuit breaker
  2. Locate the priming plug on top of the pump housing
  3. Fill the pump with 2-5 gallons of clean water until it overflows
  4. Replace the plug tightly to seal
  5. Restore power and open a faucet to bleed air
  6. Monitor for steady water flow and normal pump cycling

You turn on the faucet and hear your pump running, but only air and sputtering water come out; this is a common sign that you may need how to prime a deep well water pump. Or maybe nothing at all. This frustrating scenario means your well pump has lost its prime—the water needed inside the pump to create suction and draw more water from your well.

Priming means filling the pump housing and suction line with water so the pump can create suction and move water again. Without this vital step, your pump runs dry, which can lead to overheating, costly repairs, and days without water.

Why does this happen? Power outages, air leaks in the suction line, a faulty foot valve, or even seasonal changes in your well’s water level can all cause your pump to lose prime. For most above-ground jet pumps, priming is a manageable DIY task. Submersible pumps typically don’t require priming once installed.

I’m Mack Blair, and over my 30+ years in the well and pump industry across Indiana, I’ve helped countless homeowners understand how to prime a deep well water pump and get their water flowing again. Whether you’re tackling this yourself or need professional support, this guide will walk you through every step with clarity and confidence.

infographic showing common causes of lost prime including air leaks in suction lines, foot valve failure, low well water levels, power outages, and extended pump inactivity - how to prime a deep well water pump infographic

Why Your Well Pump Loses Prime and How to Tell

When we talk about deep well pumps, it’s important to understand the two main types and their priming needs. The first type, and the primary focus for priming, is the jet pump system. These pumps sit above ground and rely on suction to pull water from your well. Jet pumps can be used for both shallow and deep wells (often called “convertible jet pumps” for deeper applications, sometimes reaching 90+ feet). These are the systems that most frequently require priming.

The second type is the submersible pump. As their name suggests, these pumps operate entirely underwater, submerged deep within the well itself. Because they are always surrounded by water, submersible pumps generally hold their prime much better and, in most cases, do not need to be primed after their initial installation. They push water upwards rather than relying on suction, making them inherently less prone to losing prime due to air in the lines.

If you have a jet pump for your deep well system in Indianapolis or the surrounding areas, understanding the signs and causes of a lost prime is crucial.

Signs Your Well Pump Needs Priming:

  • Low Water Pressure: You might notice a significant drop in water pressure at your faucets, showers, or other water-using appliances. The water might come out in a weak trickle or sputtering bursts.
  • Inconsistent Water Flow: The water flow might fluctuate, going from strong to weak and back again, or stopping and starting intermittently.
  • Gurgling Sounds: You might hear unusual gurgling or hissing noises coming from your pipes or the pump itself. This is often the sound of air moving through the system.
  • Pump Motor Running But No Water: The pump motor is clearly working; you can hear it humming, but no water is being delivered to your home. This is a classic sign of a lost prime.
  • Frequent Cycling or Continuous Running: The pump might turn on and off more often than usual without building proper pressure, or it might run continuously without ever shutting off, indicating it’s struggling to create suction. If your deep well pump runs continuously without building pressure, shut off power and investigate; continuous running can indicate loss of prime, a leak, or a control issue.

Common Causes for a Deep Well Pump to Lose Its Prime:

  • Air Leaks in the Suction Line: This is arguably the most common culprit. Even tiny cracks or loose fittings in the suction line (the pipe running from the pump to the well) can allow air to seep in, breaking the vacuum needed for the pump to draw water. Think of it like trying to drink through a straw with a tiny hole in it—you’ll mostly get air!
  • Foot Valve Failure: The foot valve is a one-way check valve located at the very bottom of the suction line inside your well. Its job is to prevent water from flowing back down into the well when the pump isn’t running, thus keeping the suction line full. If this valve fails or becomes clogged, water can drain out of the line, allowing air to enter.
  • Low Water Level in the Well: If the water level in your well drops too low—perhaps due to drought, heavy usage, or seasonal changes—the foot valve might become exposed to air. Once air enters the suction line, the pump will lose its prime.
  • Water Drainage After Maintenance: If you’ve recently had work done on your well system, such as pipe repairs, filter changes, or even just turning off the pump for an extended period, the water in the suction line might have drained out, leading to a lost prime.
  • Power Outages: While not a direct cause of prime loss, a power outage can sometimes contribute. When power is restored, if there are any existing minor leaks or a slightly faulty foot valve, the sudden restart can exacerbate the problem and cause the pump to lose its prime.
  • Malfunctioning Pressure Vacuum Control: A faulty control or valve near the pump can introduce air or prevent proper pressure changes, making priming difficult.

Here’s a quick comparison of jet pumps and submersible pumps to clarify their priming needs:

FeatureJet Pumps (Deep Well Convertible)Submersible Pumps (Deep Well)
LocationSits above ground, near the wellheadSubmerged inside the well, below the water level
MechanismUses suction (and sometimes an ejector) to pull waterPushes water upwards
Priming NeedsRequires priming initially and if prime is lostGenerally does not require priming after installation
Prime FrequencyMore susceptible to losing prime, may need re-priming occasionallyRarely loses prime; typically holds prime better
Well DepthCan handle deep wells (up to 90+ feet with convertible models)Designed for deeper wells, pushing water from significant depths
Noise LevelCan be audible as they operate above groundVery quiet, as they operate underwater

Understanding the Key Components

To successfully prime your deep well jet pump, it helps to know the main parts you’ll be interacting with:

  • Pump Housing: This is the main body of the pump where the impeller and other internal mechanisms are located. It’s where you’ll typically find the priming plug.
  • Suction Line: This is the pipe that extends from your pump down into the well, drawing water upwards. Air leaks in this line are a prime suspect for lost prime.
  • Check Valve: Often located near the pump or within the system, a check valve is a one-way valve that prevents water from flowing backward towards the pump when it’s off. This helps maintain pressure in your system.
  • Foot Valve: As mentioned, this is a critical one-way valve at the very bottom of your suction line in the well. It keeps the water in the suction pipe from draining back into the well, which is essential for maintaining prime.
  • Pressure Tank: This tank stores water under pressure, providing a reserve supply and preventing the pump from cycling on and off every time you open a faucet. It helps maintain consistent water pressure in your home.
  • Pressure Switch: Usually mounted near the pressure tank, this electrical switch monitors the water pressure in the tank. It signals the pump to turn on when pressure drops below a set point and turn off when it reaches the desired high-pressure setting.
  • Priming Plug: This is a removable plug, typically located on the top of the pump housing or casing, designed specifically for filling the pump with water during the priming process.

Signs Your Deep Well Pump Needs Priming

If you’re experiencing any of these issues with your water system in the Indianapolis area, it’s a strong indicator that your deep well jet pump has lost its prime and needs your attention:

  • Sputtering Water from Taps: This is often the first and most common sign. When you turn on a faucet, you get a mix of water and air, causing the water to sputter and spit out.
  • Complete Loss of Water Flow: The most frustrating sign – you turn on a tap, and absolutely no water comes out, even though you can hear the pump motor running.
  • Pump Cycles Frequently: Your pump turns on and off rapidly, much more often than usual, without seeming to build up sufficient water pressure in the system. It’s struggling to do its job.
  • Pump Runs Continuously Without Building Pressure: The pump motor runs constantly, but the pressure gauge on your tank (if you have one) shows little to no pressure buildup, and still no water flows from your taps. This indicates a complete failure to create the necessary suction.

Gather Your Tools and Prioritize Safety

Before we dive into how to prime a deep well water pump, confirm you’re working with an above-ground jet pump (submersibles usually aren’t primed this way). A little preparation goes a long way in making this a smooth and safe process.

Tools and Supplies Needed:

  • Clean, potable water: Have enough clean water to fill the pump housing and suction line (amount varies by piping length).
  • Wrench (pipe or adjustable): You’ll need this to remove and tighten the priming plug.
  • Funnel: A funnel will help you pour water into the priming port without making a mess.
  • Garden hose (lead-free recommended): While not always essential, a clean, lead-free garden hose can be helpful for flushing or if you need to access a water source for priming that’s not easily pourable from a bucket.
  • Teflon tape (thread seal tape): This will be used to ensure an airtight seal when you replace the priming plug.
  • Safety goggles and gloves: Always protect your eyes and hands when working with pumps and plumbing.

Safety First: How to Prime a Deep Well Water Pump Securely

Working with electrical pumps and water requires strict adherence to safety protocols. We cannot stress this enough: safety is paramount.

  1. Turn Off All Power to the Pump: This is the most critical step. Locate the circuit breaker that controls your well pump (it’s usually labeled, but if not, you might need to flip breakers until the pump is confirmed off). Ensure the power is completely disconnected to prevent accidental startup and electrocution. If your pump is plugged into a GFCI outlet, check that it hasn’t tripped. For more details on safely checking and resetting breakers, consult this guide on how to safely check and reset a circuit breaker.
  2. Close All Water Supply Valves (Optional but Recommended): Close indoor faucets before restarting the pump so it can build pressure; then open one faucet slowly to bleed air.
  3. Notify Household Members: Let everyone in your home know that you’re working on the water system and that the power to the pump is off. This prevents anyone from accidentally turning the pump back on or expecting water.
  4. Wear Protective Gear: Put on your safety goggles and gloves.
  5. Inspect for Damage: Before you begin, take a moment to visually inspect your pump and visible piping for any obvious cracks, leaks, or loose connections. Addressing these before priming can save you a lot of frustration.

How to Prime a Deep Well Water Pump in 6 Simple Steps

Now that we’re prepared and safety measures are in place, let’s walk through the process of how to prime a deep well water pump. This DIY task focuses on creating a pressure vacuum within the pump, allowing it to draw water from your well and restore your home’s water supply.

person carefully pouring water from a bucket into the pump's priming port using a funnel - how to prime a deep well water pump

Step 1: Turn Off Power and Close Faucets

As emphasized, safety comes first.

  • Locate the circuit breaker dedicated to your well pump, typically found in your main electrical panel. Flip it to the “OFF” position. Double-check that the pump is indeed off by trying to run water from a faucet—nothing should come out.
  • Close all faucets and taps inside your house. This helps the system build pressure efficiently once the pump is running again, preventing air from being drawn back in through open fixtures.

Step 2: Locate and Open the Priming Plug

  • Your deep well jet pump will have a dedicated priming plug (sometimes called a prime plug) on its housing. This is usually a small, threaded plug located on the top of the pump casing.
  • Using your wrench, carefully remove the priming plug. Be prepared for a small amount of water or air to escape.
  • While the plug is off, take a moment to inspect the priming port for any debris or obstructions. You can also quickly check the plug itself for any signs of wear or damage.

Step 3: Fill the Pump with Water

This is the core of the priming process.

  • Place your funnel into the priming port.
  • Begin slowly pouring clean, potable water into the pump casing. Take your time to allow any trapped air to escape from the system. You might hear gurgling sounds as the air is pushed out.
  • Continue filling the pump until water begins to overflow consistently from the priming port. This indicates that the pump casing and the suction line are full of water. For a typical deep well jet pump, this might take anywhere from 2 to 5 gallons, possibly more depending on the length and diameter of your suction line.

Step 4: Replace the Priming Plug

Once the pump is full:

  • Before replacing the plug, take a moment to clean the threads of the plug and the port.
  • Wrap new Teflon tape (thread seal tape) around the threads of the priming plug. This is vital for creating an airtight seal, preventing future air leaks that could cause you to lose prime again.
  • Carefully screw the priming plug back into place. Use your wrench to tighten it securely, but don’t overtighten, as this can damage the plug or the pump housing. The goal is an airtight, watertight seal.

Step 5: Restore Power and Open a Faucet

With the pump now full of water and sealed:

  • Return to your electrical panel and flip the circuit breaker for the well pump back to the “ON” position.
  • You should hear the pump start to run.
  • Immediately open a nearby faucet (a utility sink faucet or an outdoor spigot is often best) very slowly. This allows any remaining air in your plumbing lines to escape. Let the water run, even if it’s sputtering at first.

Step 6: Check for Success

  • Monitor the water flow from the open faucet. It might sputter and spit air for a minute or two, but it should gradually transition to a steady, strong stream of water.
  • Listen to your pump. It should run, build pressure, and then eventually shut off as the pressure tank fills to its cut-off setting. This indicates a normal pump cycle.
  • Once you have a steady stream of water and the pump has completed its cycle, you can close the faucet.

If you now have a steady flow and normal cycling, you’ve completed how to prime a deep well water pump.

After Priming: Troubleshooting and Prevention

Successfully priming your deep well pump is a fantastic feeling, but sometimes the journey isn’t over. It’s important to know what to do if the pump still doesn’t cooperate and how to prevent this issue from recurring.

What to Do If the Pump Still Doesn’t Work

If, after following our steps for how to prime a deep well water pump, you still don’t have consistent water flow or your pump isn’t cycling normally, don’t despair. Here are some troubleshooting steps:

  1. Repeat the Priming Process: Sometimes, a single attempt isn’t enough to clear all the air, especially if there was a significant loss of prime. Go through all six steps again carefully.
  2. Check for Leaks (Again!): Even a tiny air leak on the suction side can prevent priming.
    • Inspect all visible connections on the suction line (from the pump to the well) and around the pump housing for any drips or signs of moisture.
    • Listen for hissing sounds when the pump is off, which could indicate air being drawn in.
    • If you let the filled pump sit for 10 minutes before sealing it up, and the water level continuously lowers in the pump body while sitting idle, it likely means there is a leak in the pump or plumbing.
  3. Faulty Foot Valve: A common culprit for repeated loss of prime is a failing foot valve. If it’s not holding water in the suction line, air will constantly re-enter the system. Diagnosing and replacing a foot valve usually requires pulling the pump or suction line from the well, which is a more involved task.
  4. Low Water Level in the Well: If your well’s water level has dropped significantly, the pump may be trying to draw air. This can happen during dry spells or if your well simply can’t recover fast enough for your water demands.
  5. Internal Pump Failure: Less common, but possible, is an internal issue with the pump itself, such as a damaged impeller or a broken seal. If the pump runs but makes unusual grinding noises, or if you can’t get it to prime despite all other checks, this might be the case.

For any persistent issues, or if you’re uncomfortable with further diagnosis, it’s always best to call in the professionals. Our team at Blair & Norris offers professional well and pump services throughout Indianapolis and Central Indiana, and we’re always ready to help.

How to Prevent Your Pump from Losing Prime in the Future

An ounce of prevention is worth a pound of cure, especially when it comes to your water supply! Here’s how you can minimize the chances of needing to prime a deep well water pump again:

  • Regular Inspections: Periodically inspect your pump, pressure tank, and all visible plumbing connections for any signs of leaks, corrosion, or damage. Early detection of a small leak can prevent a major loss of prime.
  • Check Valve and Foot Valve Maintenance: These crucial components are often overlooked. Regularly (e.g., annually during a well system check-up) inspect them for proper function. Replace aging check valves or foot valves proactively, as their failure is a leading cause of prime loss.
  • Seal All Air Leaks Promptly: Any leak, no matter how small, on the suction side of your pump can introduce air. Use Teflon tape on threaded connections and ensure all pipe joints are secure.
  • Maintain Well Water Levels: If possible, be mindful of your well’s water level, especially during dry periods. Avoid excessive, continuous water usage that could temporarily deplete the well and expose the foot valve.
  • Install a Low-Pressure Cutoff Switch: This device is a great investment. It automatically shuts off your pump if the water pressure (and thus the water level in the suction line) drops too low, preventing the pump from running dry and sustaining damage if it loses prime.
  • Proper Installation: Ensuring your pump and piping are installed correctly from the start is key. This includes using appropriate pipe sizes, ensuring uphill slopes from the well to the pump to avoid air pockets, and securely supporting all components. You can find more details on pump installation best practices in resources like this guide for jet pump installation.
  • Understand Component Lifespan: While the average lifespan of a deep well pump is between 15 and 25 years, individual components like pressure switches, check valves, and even the motor can have shorter lifespans. Knowing this can help you anticipate replacements. For example, some sources suggest that components like sump pumps often last around seven years, indicating that other pump components might also have varying lifespans. Regular professional inspection helps identify components nearing the end of their service life.

Conclusion

Understanding how to prime a deep well water pump is a valuable skill for any homeowner with a private well system. It’s a task you can often handle on your own, swiftly restoring your water supply and preventing potential damage to your pump from running dry. We’ve walked through the signs, the tools, the safety precautions, and the step-by-step process to get your water flowing again.

However, if you find yourself repeatedly priming your pump, or if the issue persists after a few attempts, it’s a strong indication of a deeper problem. This could range from persistent air leaks in your suction line, a faulty foot valve that’s no longer holding its seal, low water levels in your well, or even internal pump issues. These underlying problems require more than just a quick prime; they demand a professional diagnosis and lasting repair.

Protecting your investment in your well system is crucial. For complex diagnostics or if you’re simply uncomfortable with the process, especially in the Indianapolis, Carmel, Fishers, Noblesville, Westfield, Zionsville, or any of the surrounding Central Indiana areas we serve, trust the experts at Blair & Norris. With over 75 years of experience, we’re a family-owned business known for ethical, high-quality service, and we offer 24/7 live phone support to ensure you’re never left high and dry.

If priming doesn’t restore a steady flow, contact Blair & Norris for help diagnosing the cause of how to prime a deep well water pump. Visit our contact page to get started.